Duty history, load cycles and actual operating conditions
The assessment starts with what is known about the equipment: age, use, load spectrum, operating time, maintenance, repairs, modifications, incidents and previous findings.
Where operating hours or load spectra were not recorded, we examine which substitute data and assumptions can be justified. ISO 12482 principles are used where relevant.
Load cycles, operating history and design data
- operation data, counters, cycles or production data
- maintenance history and repairs
- previous inspection reports and open findings
- changed use, overload or incident history