Service

Competent inspection of cranes and lifting accessories

We perform initial, periodic and extraordinary inspection of cranes and lifting accessories within our certified scope. The report sets out equipment status, findings and required actions.

Need help with enterprise of Competence? Approved S1 Enterprise of Competence • Type C
Call us
Overview

What does competent inspection of lifting equipment involve?

Send us the equipment type, location and previous report if available. We agree on the applicable inspection type, documentation and any functional tests. The statutory basis includes chapter 13 of the Norwegian Regulations concerning the Performance of Work and sections 8-6 and 8-7 of the Regulations concerning Administrative Arrangements.

Initial inspection before equipment is put into service

Initial inspection is used when new or used lifting equipment is put into service for the first time, when equipment is installed or assembled at a new location, or when the previous inspection basis is not sufficient. The requirement is particularly linked to the Regulations concerning the Performance of Work section 13-3 when safety depends on installation or assembly, and to section 13-1 when the equipment is work equipment for lifting suspended loads or lifting accessories.

We review available documentation and compare it with actual execution, marking, configuration, capacity and intended use. When needed, involvement level, verification scope, functional verification and testing are defined.

The result is documented in a report/certificate in line with the Regulations concerning the Performance of Work section 13-4. When the basis is sufficient and the inspection is satisfactory, initial inspection may support issue of a certificate or statement for the equipment.

Initial inspection: documentation, marking and conformity

  • agreement between documentation, marking and actual equipment
  • declaration, instructions, certificates, drawings and test basis
  • whether equipment is installed, configured and marked for intended use
  • whether design review, functional test or load test is needed

Periodic inspection of cranes and lifting accessories

Periodic inspection is planned and recurring inspection of lifting equipment in service. The Regulations concerning the Performance of Work section 13-2 require competent inspection of work equipment listed in section 13-1 normally every 12 months, and more often if environment, use, condition or other factors make this necessary.

The inspection is performed against the equipment type, manufacturer requirements, relevant standards, previous reports and internal instructions/checklists. The Regulations concerning Administrative Arrangements section 8-7 require that inspection by an enterprise of competence particularly covers safety-relevant parts, wear, cracks, damage, corrosion, function testing with appropriate loads, protective devices and required instructions for use, operation and maintenance.

The report identifies nonconformities, restrictions or observations that require follow-up before the next inspection.

Periodic inspection: condition, function and history

  • identification, marking, WLL/SWL and traceability
  • visual condition, wear, deformation, corrosion and damage
  • function, safety devices, limitations and safe use
  • previous findings, open nonconformities, repairs and need for follow-up

Extraordinary inspection after damage, repair or modification

Extraordinary inspection is used when lifting equipment has been affected by conditions outside ordinary periodic inspection. The Regulations concerning the Performance of Work section 13-2 require competent inspection when work equipment has been exposed to significant overload, after major repairs or modifications, and when equipment that has not been used for the last six months may represent a hazard when taken back into use.

We identify the triggering condition, define the affected area and establish the inspection basis. For new, changed, repaired or affected areas, initial-inspection logic and the requirements in section 13-3 are applied as needed, especially when safety depends on new installation, assembly, repair or changed configuration.

Remaining life and need for further assessment can be included where history, condition or lack of data increases uncertainty. The result is documented in a report and can provide updated status or certificate basis where relevant.

Extraordinary inspection: affected components and remedial work

  • what has been damaged, repaired, modified, overloaded or changed
  • whether load path, stability, WLL, geometry or safety functions are affected
  • whether documentation is still valid or must be supplemented
  • whether design review, technical verification, test or follow-up inspection is required

Inspection reports, findings and follow-up

All inspections are documented by report. The Regulations concerning the Performance of Work section 13-4 require documentation of inspection by an enterprise of competence, including certification that the work equipment is completely safe to use. The documentation must be kept so it can be presented to public authorities, be available to the enterprise of competence and follow the equipment on change of ownership.

Findings are classified so the customer and inspector understand whether the condition is a nonconformity, restriction, observation or comment, and what is required for continued use or closure. The report describes what has been inspected, what was observed, the status of the equipment and which actions or restrictions apply. Owner/employer remains responsible for ensuring that equipment is used, maintained, repaired and followed up in accordance with the documented status and any limitations.

Documents and inspection history needed

  • equipment type, manufacturer, model, serial number and location
  • previous reports, certificates and open findings
  • instructions, declaration and technical documentation
  • photos of equipment, marking, load path and any damage